Two long arc xenon lamps rated at 20kW each provide a full spectrum "sunlight" simulation. There is enough ultra-violet light emitted to permit accelerated aging studies with plastics and other materials.
This is a plan view of the high light room. The two 20kW xenon lamps are above lamp barriers which are 7 feet off the floor. Light measurements were taken with 9 sensors in the configuration shown, and the results are displayed in the table below.
Spectral Output of the Xenon Lamps
| Sensor Position (see diagram) |
PAR Level | ||
|---|---|---|---|
| 1' Below Barrier | 3' Below Barrier | 5' Below Barrier | |
| 1 | 1800 | 1150 | 750 |
| 2 | 2150 | 1150 | 800 |
| 3 | 1750 | 1100 | 780 |
| 4 | 1100 | 1050 | 880 |
| 5 | 1250 | 1100 | 990 |
| 6 | 1050 | 1000 | 920 |
| 7 | 1900 | 1100 | 810 |
| 8 | 2300 | 1200 | 860 |
| 9 | 1900 | 1050 | 820 |
| AVERAGE | 1689 | 1100 | 846 |
| AVERAGE (excluding 4,5,6) | 1967 | 1125 | 803 |
| Notes: | New lamp on left side of room Unknown hours on right side lamp Minimum room temp obtained about 16°C |
||